OEM sizes magnetic flap level gauge for cold room

  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
  • OEM sizes magnetic flap level gauge for cold room Manufacturers, OEM sizes magnetic flap level gauge for cold room Factory, Supply OEM sizes magnetic flap level gauge for cold room
OEM sizes magnetic flap level gauge for cold room
  • XINRUIHUA
  • Shandong, China
  • about 30 days
  • 3000 pcs/month

1. Magnetic flap level gauge has wide application range and various installation forms, suitable for liquid level measurement of any medium.
2. The measured medium of magnetic flap level gauge is completely isolated from the indicating structure, with good sealing performance and anti-leakage. It is suitable for liquid level measurement under high temperature and high pressure corrosion conditions with high reliability.
3. The magnetic flap level gauge sets on-site instructions, remote transmission, alarm control switch in one, two-color indicator with luminous, continuous and intuitive, eye-catching.
4. The magnetic flap level gauge has good vibration resistance.
5. The magnetic flap level gauge is with magnetic steel teach the positive.

Industrial refrigeraiton magnetic flap level gauge with OEM sizes


Introduction

     The magnetic flap level meter uses the magnetic float inside it to produce magnetic displacement with the change of liquid level, so that the red and white magnetic column of the liquid level window can be turned to indicate the height of liquid level. When the float rises, the magnetic column turns white to red. When the float falls, it turns red to white. Red always indicates the liquid level.

water tank level gauge


   It can be widely used in the fields of oil processing, municipal administration, food processing, chemical industry, water treatment, pharmacy, electric power, paper making, metallurgy, ship and boiler for liquid level measurement, control and monitoring.

oil tank level gauge

Main Parameter


Product name

Magnetic flap level gauge

Model

UHZ-T

Measuring range

150-8000mm

Work pressure

0.6, 1.0, 2.5, 4.0, 6.4, 100 Mpa

Operating temperature

F: 120℃; G: 200℃; H: 450℃

Accuracy

±10mm

Medium density

0.5-2.0 g/cm3

Media density difference

150kg/m3 (Measurement boundary)

Environmental vibration

Frequency: ≤ 25Hz; amplitude: ≤ 0.5mm

Follow speed

0.08 m/s

Medium viscosity

0.4 Pa.s   For mediums with high viscosity or media that are easy to crystallize when measuring low temperatures, a heated jacket type level gauge can be used.

Process connection

Bypass side mounting flange: DN20

Switch option

Ordinary or explosion-proof

Transmitter options

Reed liquid level transmitter, magnetostrictive liquid level transmitter, full intelligent table display liquid level transmitter

Application range

Medium level detection of various towers, tanks, trough-shaped containers and boilers, high temperature and high pressure corrosive environment

MOQ

500 pcs

Brand

XINRUIHUA

Lead time

About 30 days

Packaging

carton, and package can be customized

Port

Qingdao


water tank level meter

① Indicator  ② Magnetic float  ③ Float  ④ Connecting flange  ⑤ Blowdown valve


Features of magnetic flap level gauge:
     1. It is applicable to the liquid level measurement of the liquid medium in the container. Besides the on-site display, it can be equipped with remote transmitter, liquid level controller, etc
     2. The display is intuitive and eye-catching, and the display direction can be changed according to the user's requirements. 3. The measurement range is large, not limited by the height of the container. A kind of
     4. The display component is completely isolated from the tested medium, so it has good sealing performance, reliability and safety. 

     5. Simple structure, convenient installation and maintenance. 

     6. Corrosion resistant and explosion-proof.


Product Details

water tank level gauge

oil tank level gauge

Precautions:

     (1) During transportation, the magnetic flap level gauge will use a nylon strap to fix the float near the float before leaving the factory;

     (2) A valve should be installed between the magnetic flap level gauge and the container to cut off the material during cleaning and maintenance;

     (3) Any magnetic object is not allowed to be near the cylinder of the magnetic flap liquid level gauge, and the use of iron clamps is strictly prohibited, otherwise it will affect the normal operation of the magnetic flap liquid level gauge;

     (4) When the top-mounted magnetic flap liquid level gauge is installed, the magnetic flap liquid level gauge protection conduit and the main conduit must be kept vertical and on the same extension line, the floating ball connecting rod cannot be bent and must be installed vertically;

     (5) Because the joint between the buoy and flange of the 304 lined PTFE anticorrosive magnetic flap level gauge adopts a unique sealing structure, it needs to be assembled with special tools. In order to ensure the reliability of the seal, it is prohibited to dismantle without permission;

     (6) After the magnetic flap level gauge is installed, it needs to be calibrated with magnetic steel to make the flaps above zero appear white;

     (7) When the magnetic flap level gauge is put into operation for the first time, the upper liquid inlet valve should be opened first, and then the lower liquid inlet valve should be slowly opened to allow the liquid medium to flow in smoothly to avoid the liquid medium from rising rapidly with the float and causing the Film flip failure or disorder (such phenomenon occurs, please use magnetic steel to correct);

     (8) There should be no solid impurities in the float of the magnetic level gauge, so as not to block the float. Be sure to clean the float regularly to remove internal impurities;

     (9) For ultra-long magnetic flap liquid level gauge (measurement range is greater than 4m), the cost of logistics and transportation is high, and it is generally made in sections.

water tank level meter


Installation and maintenance
     1. The magnetic flap level gauge must be installed vertically to ensure that the floating ball assembly can move up and down freely in the main pipe. 

     2. It is not allowed to have a magnet near the main body of the liquid level gauge, otherwise it will directly affect the correct operation of the magnetic flap level gauge. 
     3. After themagnetic flap level gauge is installed, it is necessary to use magnetic steel to calibrate the turning column guide once, so that the display below the zero position is red and zero White above bit. 
     4. When the magnetic flap level gauge is put into operation, open the valve of the lower liquid guide pipe first to let the liquid medium enter the main pipe smoothly, so as to avoid the liquid medium The floating ball component of the mass belt rises rapidly, resulting in the overturning failure and random overturning of the column. If this happens, it can be recalibrated with magnetic steel after the liquid level is stable.
     5. In order not to damage the floating ball assembly during transportation, take the floating ball assembly out of the main pipe of the magnetic flap level gauge before delivery. After the liquid level gauge is installed, open the drain flange at the bottom, and then install the floating ball assembly into the main pipe again. Pay attention to that the heavy end of the floating ball assembly is upward, and it cannot be inverted. 
      6. According to the medium condition, the drain flange can be opened regularly to clean the precipitate in the main pipe

water tank level gauge


oil tank level gauge


Related products:

 Magnetic Flap Level Gauge, Plate level gauge, Pressure controller, Differential pressure switch, Digital temperature display, Iron Shell Thermometer, Pressure sensor, temperature probe, Temperature controller, Time relay, Pressure gauge, Explosion-proof pressure transmitter, Temperature platinum thermal resistance, Float level controller



water tank level meter

       We mainly provide a variety of refrigeration accessories,screw refrigeration compressors and accessories, piston refrigeration compressors and accessories, Industrial refrigeration system accessories, Cold storage installation accessories, Ammonia chemical protection products, Refrigeration instrument and gauge, mobile cold storage and so on.

water tank level gauge

oil tank level gauge

     Shandong Ruihua Refrigeration Equipment Co.,Ltd is found in 1989, as an engineering, manufacturing, installation and maintenance refrigeration equipment company. We can also provide environmental protection and energy saving refrigeration solutions in accordance with users' requirements.

water tank level meter


Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right